What is the registration process for Class B medical devices with HSA in Singapore? What steps are involved?
Release time:2025-01-09 11:14:00 The author: source:
The registration process for Class B medical devices with the Health Sciences Authority (HSA) in Singapore involves several structured steps. The process ensures that the device meets all regulatory requirements for safety, performance, and quality before it can be marketed in Singapore.

The registration process for Class B medical devices with the Health Sciences Authority (HSA) in Singapore involves several structured steps. The process ensures that the device meets all regulatory requirements for safety, performance, and quality before it can be marketed in Singapore. Below are the detailed steps involved in the registration process:

1. Pre-Application Preparations

a. Establish an Authorized Representative (AR)

  • Requirement: If your company is based outside of Singapore, you must appoint an Authorized Representative (AR) based in Singapore. The AR acts as the liaison between the manufacturer and HSA for regulatory matters.
  • Role of AR: The AR is responsible for the registration of the device, as well as ensuring that post-market surveillance, adverse event reporting, and any regulatory issues are handled according to Singapore's laws.

b. Ensure Compliance with Regulatory Standards

  • Ensure that the device complies with international standards such as:
    • ISO 13485 (Quality Management System),
    • ISO 14971 (Risk Management),
    • IEC 60601-1 (Electrical Safety, if applicable),
    • ISO 10993 (Biocompatibility, if applicable), etc.
  • Confirm that clinical evidence, risk management documentation, and other supporting documents are ready and meet the requirements.

2. Application Submission via the Health Products Regulation System (HPRS)

a. Create an Account on HPRS

  • Access HPRS: Before submitting an application, create an account on the Health Products Regulation System (HPRS), which is the online platform for submitting medical device applications to HSA.
  • Provide Company Details: Register your company and AR’s details on HPRS to link your application with the appropriate entity.

b. Submit the Application

  • Device Information: Complete the medical device registration application form on HPRS with detailed information about the device, including:
    • Device classification (Class B),
    • Intended use,
    • Device description,
    • Device components,
    • Manufacturing details, etc.
  • Supporting Documentation: Attach the following supporting documents:
    • Device labeling and Instructions for Use (IFU),
    • Risk Management Report,
    • Clinical Evaluation Report (if applicable),
    • ISO 13485 certificate (for manufacturing sites),
    • Test reports (e.g., electrical safety, biocompatibility, etc.),
    • Device Classification Report (to justify the Class B classification).

c. Submit Application Fees

  • Pay the application fee through the HPRS platform. The fee depends on the device type and classification.

3. HSA’s Evaluation of the Application

a. Initial Screening

  • Review for Completeness: HSA will first review the submitted application to ensure all required information and documents are complete.
  • Clarifications: If any documents are missing or there are discrepancies in the information provided, HSA will request clarifications or additional details from you.

b. Technical Evaluation

  • Risk Assessment: HSA evaluates the device's risk classification (Class B), verifying that the information provided is consistent with Class B medical device requirements. This includes assessing the device’s safety, performance, and quality.
  • Documentation Review: HSA will assess the submitted technical documentation, including risk management reports, clinical data (if applicable), and conformity to international standards (e.g., ISO 13485, ISO 14971).

c. Compliance Check

  • Ensure International Standards: HSA will verify compliance with relevant international standards (e.g., ISO 13485, ISO 14971). The device’s safety, performance, and manufacturing processes are reviewed.
  • Adverse Event Monitoring: HSA will also assess your post-market surveillance and vigilance systems, ensuring that you have measures in place to monitor the device's performance in the market.

4. HSA Approval and Issuance of Registration Certificate

a. Registration Decision

  • Approval: If HSA determines that the device complies with all regulatory requirements, it will approve the registration.
  • Rejection: If the device does not meet the requirements, HSA may reject the application or request significant changes.

b. Issuance of Registration Certificate

  • Once approved, HSA will issue the medical device registration certificate for the Class B device.
  • The registration is typically valid for 5 years, after which renewal is required.

5. Post-Registration Compliance and Maintenance

a. Post-Market Surveillance (PMS)

  • Ongoing Monitoring: After registration, you must monitor the device’s performance in the market, gather data on any adverse events, and submit periodic PMS reports to HSA.
  • Adverse Event Reporting: You are required to report any serious adverse events within 10 working days and non-serious events quarterly.

b. Renew Registration

  • 5-Year Renewal: Registration for Class B medical devices is valid for 5 years. You need to submit an application for renewal before the registration expires. The renewal application typically involves submitting updated post-market data, compliance information, and any changes to the device.

c. Notify HSA of Changes

  • Changes in the Device: If there are any changes to the device (e.g., design, materials, intended use, manufacturing site), you must notify HSA. Significant changes may require approval, while minor changes might only need notification.

Summary of the Steps Involved in Class B Medical Device Registration with HSA

  1. Pre-Application:

    • Appoint an Authorized Representative (if needed).
    • Ensure compliance with relevant international standards and prepare all necessary documents.
  2. Application Submission:

    • Create an HPRS account.
    • Submit the application form with required device information and supporting documents.
    • Pay the application fees.
  3. Evaluation by HSA:

    • Initial screening for completeness.
    • Technical evaluation (risk assessment, standards compliance check).
    • HSA may request additional information or clarifications.
  4. Approval and Issuance of Registration Certificate:

    • HSA issues the registration certificate if the device meets all requirements.
  5. Post-Registration Compliance:

    • Conduct post-market surveillance and report adverse events.
    • Apply for registration renewal after 5 years.
    • Notify HSA of any significant changes to the device.

By following these steps and ensuring compliance with the necessary regulations and standards, you can successfully navigate the Class B medical device registration process with HSA in Singapore.