What are the requirements for handling D-class medical device registration with Vietnam MOH?
发布时间:2025-01-24 作者:
Handling the registration of D-class medical devices with the Vietnam Ministry of Health (MOH) involves a comprehensive and stringent process. D-class devices are considered high-risk medical devices and require significant regulatory oversight.

Handling the registration of D-class medical devices with the Vietnam Ministry of Health (MOH) involves a comprehensive and stringent process. D-class devices are considered high-risk medical devices and require significant regulatory oversight. Below are the key requirements for handling the registration:

1. Local Authorized Representative

  • Requirement: Foreign manufacturers must appoint a local authorized representative in Vietnam to act on their behalf for the registration process and communicate with the Ministry of Health.
  • Role: The local representative submits the application, ensures compliance with local laws, and acts as a liaison between the company and the Vietnam MOH.

2. Product Classification

  • Requirement: Confirm that the device is classified as D-class under Vietnam’s medical device classification system. This classification is based on the level of risk associated with the device.
    • D-class devices are high-risk devices, such as implantable devices, life-sustaining devices, and devices used in critical surgeries.
  • Importance: D-class devices are subject to more detailed scrutiny due to their higher potential risk to patients and users.

3. Document Preparation

The following documents must be prepared and submitted to the Vietnam MOH:

  • Registration Application Form: This form, provided by the Vietnam MOH, must be completed accurately.

  • Product Technical Dossier: A detailed dossier that includes:

    • Product Description: Information on the device’s design, function, intended use, and clinical applications.
    • Manufacturing Process and Quality Control: Documentation demonstrating that the manufacturing process meets international standards like Good Manufacturing Practice (GMP) and ISO 13485.
    • Clinical Data/Trials: If required, clinical trial data or post-market surveillance data to prove the safety and effectiveness of the device. This is particularly important for D-class devices.
    • Risk Management Documentation: A risk analysis report (usually based on ISO 14971) to show how risks associated with the device are identified and mitigated.
    • Labeling: Product labeling and Instructions for Use (IFU) must comply with Vietnamese regulations and should be in Vietnamese or bilingual (Vietnamese and English).
  • Certificate of Free Sale (CFS): A certificate issued by the regulatory authority in the country of origin, proving that the device is legally marketed and available for sale in the home country.

  • Good Manufacturing Practice (GMP) Certificate: Certification that the manufacturer adheres to GMP standards, ensuring the device is manufactured with the required quality controls.

  • Quality Management System (QMS) Certificate: Evidence of certification in ISO 13485 or equivalent, ensuring that the device meets quality standards.

  • Declaration of Conformity: A statement from the manufacturer asserting that the device complies with relevant international standards.

  • Risk Assessment and Safety Data: Evidence that the device has been assessed for potential risks and the methods used to minimize those risks.

4. Submit the Registration Dossier

  • Submission Process: Once the documents are compiled, the dossier must be submitted to the Medical Device Administration (MDA) under the Vietnam Ministry of Health.
  • Responsibility: The local authorized representative handles the submission to ensure that all required documents are complete and accurate.

5. Review and Evaluation by MOH

  • Review Process: The Vietnam MOH will review the dossier to evaluate the device’s compliance with regulatory requirements. The MOH may request additional information or clarification.
  • Inspection: Depending on the device, the MOH may conduct a site inspection of the manufacturing facility or request more detailed clinical or safety data.
  • Timeframe: For D-class devices, the review process may take several months due to the complexity and potential risks involved.

6. Registration Approval

  • Approval: If the dossier meets all regulatory requirements and the review process is successful, the MOH will issue a Medical Device Registration Certificate.
  • Validity: The registration certificate is valid for 5 years, after which it needs to be renewed.

7. Post-Market Surveillance and Reporting

  • Post-Market Obligations: After registration, the manufacturer or importer is required to:
    • Monitor the safety and performance of the device.
    • Report any adverse events, recalls, or quality issues to the Vietnam MOH.
    • Comply with any additional reporting requirements or inspections requested by the MOH.
  • Periodic Audits: The MOH may conduct periodic inspections or audits of the device in the market.

8. Device Renewal

  • Renewal: D-class device registrations are valid for 5 years. To maintain market access, manufacturers must apply for renewal before the expiration date.
  • Documents for Renewal: Updated technical documents, post-market surveillance data, and any changes to the manufacturing process or device design.

9. Compliance with International Standards

  • Requirement: D-class devices must comply with recognized international standards, such as:
    • ISO 13485 (Quality Management System for Medical Devices)
    • ISO 14971 (Risk Management for Medical Devices)
    • IEC 60601 (Safety Standards for Medical Electrical Equipment), where applicable.

Key Considerations

  • Clinical Data: For high-risk D-class devices, clinical trial data may be required to demonstrate safety and efficacy. The MOH may request evidence of post-market clinical follow-up as well.
  • Language Requirements: All documents must be provided in Vietnamese or bilingual (Vietnamese and English). This includes labeling, instructions for use (IFU), and regulatory documents.
  • GMP Compliance: Manufacturers must ensure that their facilities comply with GMP standards to demonstrate the device’s quality throughout its lifecycle.

Conclusion

The requirements for handling D-class medical device registration with the Vietnam MOH involve thorough documentation, adherence to international standards, and compliance with regulatory processes. Working closely with a local authorized representative and ensuring that all requirements are met will help facilitate a smooth registration process.

louis-reed-pwcKF7L4-no-unsplash.jpg

Contact Us:

Whatsapp or Wechat:+86 15816864648;email address:hito.lin@grzan.cn